Technical parameters |
Input voltage | DC24V |
Iron generating way | Corona discharge way |
Display LED | H.V(green) | High voltage normal operation indicator light is on |
ALARM (red) | The indicator light is on when discharge is abnormal and electric circuit is abnormal; |
CLEANIKIG (yellow) | The indicator is on and the buzzer prompts when reaching the set cleaning time. |
Voltage regulation mode/ applied voltage | High frequency AC way/±2200V |
Ion balance | Within ±20 V(measuring distance 300mm,supply air pressure 0.3MPa) |
Destaticizing time | 2.0S(measuring distance 300mm, supply air pressure 0.3MPa) |
Cleaning timer set time | Can be set within 0-999 hours |
Ozone generation amount(ppm ) | Within 0.03pp m(measuring distance 50mm,supply air pressure 0.2MPa ) |
Applicable fluid | Air(cleaning air of which the water and oil has been removed) |
Air pressure application range(MPa ) | 0.01-0.5MPa |
Use ambient temperature | Indoor 0~40℃ CM0T |
Use ambient humidity | 15~75%Rh (no condensation)
|